RPV
Choose specification
Number of wire: |
Choose wire diameter, mm:
The cable is designed for telephone distribution networks where frequency is up to 10 kHz. The cable is suitable for outdoor use, indoor and moist premises. The cable is resistant to low temperature up to-25°C.
Two PE insulated solid conductors are made out of annealed copper.
Two parallel cores are flame retardant PVC sheathed, so the cable is easy to use.
Additional information
The cable fully complies with the EU Directive 2011/65/ES on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.
The cable fully conforms to the requirements of the EU Directive 2006/95/EB for Low Voltage.
Technical date | |
---|---|
Conductor resistance at +20°C | In accordance with ĮST 147738655.006:2008 |
Conductor working temeprature, max. | +70°C (under normal conditions) +160°C (in the event of short circuit) |
Rated voltage U/U0 | 380 V |
High voltage test, kV | 4 kV |
Minimum bending radius | > 5 times the cable diameter |
Operating temperatures | Mounting -5°C - +40°C Operating -30°C - +70°C |
Flame propagation | Flame test in accordance with LST EN 60332-1-2 |
Construction | |
---|---|
Conductors | Solid, annealed copper, in accordance with ĮST 147738655.006:2008 |
Insuliation | PE insulation |
Sheath | Flame-retardant plasticized PVC, O2 index >32% |
Sheath colour | Black |
See also
H05V2V2H2-F
The cable is designed for low power domestic appliance installation in domestic premises. The cable…