Contact us For registered customers Lietuvių По-русски
BASEC DNVGL

RKKB

Choose specification
Number of cores:
Choose cross-sectional area, mm²:

RKKB

The cord-cable is designed to use in devices where voltage does not exceed 100 V.

Flexible, highly soft conductor is stranded out of fine annealed copper wires.

Insulated cores are stranded together and PVC-sheathed, so the cord-cable is easy to use.

Additional information

The cord-cable fully complies with the EU Directive 2011/65/ES on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.

The cord-cable fully conforms to the requirements of the EU Directive 2006/95/EB for Low Voltage.

Technical date
Conductor resistance at +20°C In accordance with LST EN 60228+AC
Conductor working temeprature, max. +70°C (under normal conditions) +160°C (in the event of short circuit)
Thermal shock 1 h at +150°C
Rated voltage U/U0 100 V
High voltage test, kV 2 kV
Minimum bending radius > 5 times the cable diameter
Operating temperatures Mounting -5°C - +40°C Operating -15°C - +70°C
Flame propagation Flame test in accordance with LST EN 60332-1-2
Construction
Conductors Flexible, annealed copper, class 5 in accordance with LST EN 60228+AC
Insuliation PVC insulation compound type TI1, TI2 in accordance with LST EN 50363-3
Core colours Blue, red, black, grey
Sheath PVC insulation compound type TM 1, TM 2 in accordance with LST EN 50363-4-1
Sheath colour White, grey, black or upon customer request