Contact us For registered customers Lietuvių По-русски
BASEC DNVGL

RPP

Choose specification
Number of wire:
Choose wire diameter, mm:

RPP

The cable is designed for telephone distribution networks where frequency is up to 10 kHz. The cable is suitable for outdoor use, indoor and moist premises. The cable is resistant to low temperature up to-25°C.

Two PE insulated solid conductors are made out of annealed copper.

Two parallel cores are PE-sheathed, so the cable is easy to use.

Additional information

The cable fully complies with the EU Directive 2011/65/ES on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.

The cable fully conforms to the requirements of the EU Directive 2006/95/EB for Low Voltage.

Technical date
Conductor resistance at +20°C In accordance with ĮST 147738655.006:2008
Conductor working temeprature, max. +70°C (under normal conditions) +160°C (in the event of short circuit)
Rated voltage U/U0 380 V
High voltage test, kV 4 kV
Minimum bending radius > 5 times the cable diameter
Operating temperatures Mounting -5°C - +40°C Operating -30°C - +70°C
Construction
Conductors Solid, annealed copper, in accordance with ĮST 147738655.006:2008
Insuliation PE insulation
Sheath Insulation PE
Sheath colour Black

See also


H07V-R

The cable is designed for fixed installation, in mounted or fixed on surface conduits or…


R2

The cable is designed for car cable strand assembling. Designed for work when conductor temperature…

© 1958 - 2021 AB „Lietkabelis“. All rights reserved. Created by A-GAIN